ADA Compliant Signage in Fort Worth and Dallas

Tactile, braille and visual signs for rooms, restrooms, exits and wayfinding. Designed and installed for businesses across Dallas Fort Worth.

Accessible Signage for Commercial Properties
Divider

Accessible Signage for Commercial Properties

ADA-compliant signage ensures your facility is accessible and navigable for all individuals. From braille restroom signs to room identification and directional signage, compliant interior signage plays a critical role in professional environments.

Elevated Exposure Signs and Graphics provides interior signage solutions across Fort Worth, Dallas and surrounding communities that align with accessibility requirements.

Simple white building sign for TropicAir & Heat with red and blue lettering and a 817 area code phone number
ADA-compliant fire cabinet sign with a decorative wave top, featuring fire safety and phone icons
Accessible Signage for Commercial Properties

What Makes a Sign ADA Compliant?

An ADA compliant sign is a permanent sign built to the 2010 ADA Standards for Accessible Design: raised characters, Grade 2 braille, a sans serif uppercase typeface, a non-glare finish, strong contrast between text and background, and mounting on the wall beside the latch side of the door with the tactile characters between 48 and 60 inches above the floor. In Texas, the same signs also have to meet the Texas Accessibility Standards (TAS), which follow the federal rules closely.

Most of that disappears once the sign is on the wall. A visitor sees a clean sign with your room name on it. An inspector checks whether the characters sit 1/32 inch above the background, whether the braille is below the text, and whether the sign is where the standard says it belongs. We build and place every sign with the inspector's checklist in mind, then design it so it still looks like your brand.

Common ADA Signage Applications

Brushed metal ADA restroom signs for Ladies and Gents featuring tactile lettering and Grade 2 Braille
Clear acrylic 'Lounge 2' room number sign with professional metal standoffs on a white door
Illuminated green LED Exit sign mounted above a yellow 'Safety First' caution sign with a hard hat graphic
Wall-mounted building directory for 1050 Post & Paddock with clear black text and a professional silver frame
ADA-compliant office sign for Wake Financial Group with room number 205 and an interchangeable Osaic logo insert

Which Signs in Your Building Need Tactile Text and Braille

Not every sign in a building has to be tactile, and that surprises a lot of owners. The rule turns on what the sign does. A sign that names a permanent room or space needs raised characters and Grade 2 braille. A sign that points somewhere or gives general information needs readable visual characters, but not raised ones.

 Signs that need raised characters and braille

  • Restroom signs, with the pictogram and a text descriptor

  • Room numbers and suite numbers

  • Conference rooms, break rooms, storage rooms and mechanical rooms

  • Door signs at exit stairways, exit passageways and exit discharge

Signs that need legible visual characters only

  • Directional signs, such as an arrow pointing toward the restrooms

  • Informational signs, such as rules of conduct or hours of operation

 Signs the standard exempts

  • Building directories and menus

  • Occupant names, company names and logos, and building addresses

  • Temporary signs posted for seven days or less

Many signs carry both kinds of content. A suite sign with a room number, a company logo and a tenant name is the usual example. The room number is a permanent designation and has to be tactile, while the logo and the name are exempt. That is why the office sign above, with a fixed number and an interchangeable logo insert, works well for multi-tenant buildings.

Understanding Texas Accessibility Standards
Modern dimensional acrylic lobby sign mounted on a textured wall for a corporate reception area
Brushed metal ADA restroom signs for Ladies and Gents featuring tactile lettering and Grade 2 Braille
Divider

Understanding Texas Accessibility Standards

  • Letter height

  • Contrast

  • Tactile characters

  • Braille placement

  • Mounting height

While requirements vary depending on facility type, we guide clients through basic considerations to support compliance.

ADA Sign Specifications at a Glance

Requirement What the 2010 ADA Standards say
Raised characters At least 1/32 inch above the background
Character height 5/8 inch minimum, 2 inches maximum (raised characters may be 1/2 inch minimum when a separate visual sign carries the same information)
Typeface Sans serif and uppercase, with no italic, script or highly decorated styles
Braille Grade 2 (contracted) braille, placed below the corresponding text
Finish and contrast Non-glare finish, with light characters on a dark background or dark characters on a light background
Mounting height Baseline of the lowest tactile character at least 48 inches above the finished floor, baseline of the highest at most 60 inches
Location On the wall beside the latch side of the door, or on the nearest adjacent wall when the latch side has no wall space
Clear floor space 18 by 18 inches, centered on the tactile characters, beyond the swing of the door

  ADA and TAS: What Applies to a DFW Project

Texas adds a second layer on top of the federal ADA. The Texas Accessibility Standards are the state's rules, administered by the Texas Department of Licensing and Regulation (TDLR) under Chapter 469 of the Texas Government Code. The current edition is the 2012 TAS, effective March 15, 2012. Its sign requirements track the 2010 ADA Standards closely, so one correctly built sign normally satisfies both.

Where it gets practical is project size. A construction project with an estimated cost of $50,000 or more has to be registered with TDLR, and a Registered Accessibility Specialist reviews and inspects the work. Smaller projects do not have to be submitted, though a local building official can still ask for registration. In a multi-tenant building, the landlord stays responsible to the state for the tenant's construction work.

We are a sign company, not an accessibility inspector. We build signs to the standard and mount them correctly, and we will tell you when a question belongs with your architect or your Registered Accessibility Specialist. If your project is registered with TDLR, send us the sign schedule from the plans and we will match it.

Interior Integration with Brand Identity

Divider

Compliance does not mean sacrificing aesthetics.

We integrate ADA elements into your interior signage system to maintain consistency across your space.

How We Handle an ADA Signage Project

ADA signs are a small line item that causes real trouble when they go wrong, because they are usually the last thing installed before an inspection. Our process is built to catch problems while they are still cheap to fix.

 Start with the room list

We work from your floor plan, your architect's sign schedule, or a walkthrough of the space. The goal is a complete list of every sign the project needs, so nothing turns up missing on inspection day.

  Approve a proof before anything is made

Each sign goes on a proof showing the exact text, pictogram, braille translation, character size and layout. You sign off before fabrication starts, and the braille gets its own check.

 Match your brand inside the rules

We adjust colors, finishes and typefaces so the sign reads as part of your interior and still meets the contrast, finish and font requirements.

 Check the finished signs

Raised depth, braille placement and surface finish are checked against the proof before the signs leave the shop.

 Install at the right height and location

Each sign is mounted on the latch side wall with the tactile characters between 48 and 60 inches and clear floor space beside it, so the installed result matches the sign schedule.

 Common ADA Signage Mistakes and How We Avoid Them

In our experience, these problems show up on plans, on existing signs, and on new signs that looked fine when they were delivered.

Mounted on the door.

Tactile signs go on the wall beside the latch side. A sign on the door disappears from view when the door opens, and it fails the placement rule.

Decorative typefaces

Script, italic and highly decorated fonts are out, and the raised characters have to be sans serif.

Wrong height

The 48 to 60 inch range is measured to the baseline of the characters, not to the center or top of the sign plate. Two plates mounted at the same height can pass or fail depending on where the text sits on them.

Weak contrast

 Light gray on white, or brand blue on navy, looks tasteful and fails. The characters need a clear light-on-dark or dark-on-light pairing.

Braille too close to other elements

Braille sits below the text, and a raised logo or decorative border placed too near it can cause a failure.

Signs that never got updated

 When a room changes its name or number, the permanent sign for that room has to change too. A storage room or stair door missed on the original list is just as common.

ADA Signs for Offices, Clinics, Restaurants and Public Buildings in DFW

The rules are the same everywhere, but the job looks different depending on the building.

Office buildings and tenant improvements

A tenant build-out usually needs a full set of room signs on a fixed schedule, and the landlord often has building standards for finishes.

We work with property managers and general contractors to match the building standard and still meet the ADA and TAS. Our commercial property signage and corporate and office signage pages cover the rest of an interior package.

Medical and healthcare facilities

Clinics have many small rooms and patients who need to find them.

Exam room numbers, restrooms and suite signs all need tactile text. See our medical and healthcare signage page for the wider sign package.

Restaurants and retail

Restrooms are the main requirement, with the pictogram, tactile text and braille on the wall beside the door.

Our restaurant and hospitality signage page shows how those signs fit into a full dining room.

Schools, government and institutional projects

These jobs tend to involve large quantities, formal bid documents and supplier diversity goals.

We are an NMSDC-certified Minority Business Enterprise, which matters when a project has MBE spending requirements.

ADA Signage Across Fort Worth, Dallas and Surrounding Cities

Our office is at 600 W 6th St, Suite 481 in Fort Worth, and we install ADA signs across the DFW area. That includes Fort Worth, Dallas, Arlington, Grand Prairie, North Richland Hills, Saginaw, Plano, Irving, Grapevine, Hurst and Bedford. If you manage several locations, we can set one sign standard and roll it out site by site. Call (817) 634-0007 or request a free estimate and tell us how many rooms you are dealing with.

Frequently Asked Questions

Is ADA signage required for all businesses?

Any business open to the public that has permanent rooms and spaces, such as restrooms and meeting rooms, should plan on compliant signs for them. Whether a project also falls under a TDLR review depends on its size and type.

Do ADA signs require specific mounting heights?

Tactile characters must sit between 48 and 60 inches above the finished floor, measured to the baseline of the text, on the wall beside the latch side of the door.

Can ADA signage match brand colors?

Light-on-dark and dark-on-light pairings both work, and the finish has to be matte. We check your palette and suggest the closest compliant pairing when a brand color is too close to its background.

Do Texas businesses follow the ADA or TAS for signs?

Both. The ADA is the federal baseline, and the Texas Accessibility Standards apply on top of it for projects covered by the state's Architectural Barriers law. The sign requirements in the 2012 TAS closely match the 2010 ADA Standards, so a sign built correctly for one will normally satisfy the other. Your architect or a TDLR Registered Accessibility Specialist can confirm how the rules apply to your building.

Does an ADA sign go on the door or on the wall?

On the wall, beside the latch side of the door. The sign needs 18 by 18 inches of clear floor space centered on the tactile characters, outside the swing of the door. If there is no wall space on the latch side, the sign goes on the nearest adjacent wall.

Do all signs in my building need braille?

No. Braille and raised characters are required on signs that name permanent rooms and spaces, such as restrooms and room numbers, and on door signs at exit stairways. Directional and informational signs need legible visual characters but not braille. Building directories, company logos and temporary signs are exempt.

How long does it take to make ADA signs?

It depends on the number of signs, the materials, and how quickly the room list and proofs are approved. Braille and tactile work takes more care than a flat printed sign, so we give you a schedule with your proof instead of a guess up front. If you have an inspection or opening date, tell us at the start and we will plan backward from it.

 How much do ADA compliant signs cost?

Price depends on the number of signs, the material and finish, and whether installation is included. A few restroom signs and a full building package are very different jobs. Our commercial sign cost guide explains what drives pricing, and a free estimate gives you real numbers for your project.

Do I need new ADA signs after a remodel or a rebrand?

If a room gets a new name or number, the permanent sign for that room has to change with it. A remodel is also a good time to check existing signs for height, contrast and finish. Send us photos and the room list and we will tell you what needs replacing.

Can you supply signs for a whole building from one room list?

Yes. Send us the sign schedule from your plans, or a floor plan with the rooms marked, and we will quote and produce the full set so the finish and style stay consistent from the lobby to the last storage room.

Trusted by Businesses Across Fort Worth and Dallas

Elevated Exposure Signs and Graphics is committed to delivering high-quality, compliant signage solutions with integrity and professionalism.

NMSDC-Certified MBE for Government and Public Sector Projects

Elevated Exposure Signs and Graphics holds NMSDC Minority Business Enterprise (MBE) certification, Certificate No. DL327151, through the Dallas/Fort Worth MSDC. Organizations with supplier diversity requirements can work with us to meet MBE spending goals on government, institutional and corporate signage projects.

NMSDC Minority Business Enterprise (MBE) certification for Elevated Exposure Signs and Graphics LLC.

Ensure Your Facility Meets Accessibility Standards

Elevated Exposure Signs and Graphics logo - Commercial sign company in Fort Worth and Dallas.

Elevated Exposure Signs and Graphics proudly serves businesses across Fort Worth, Dallas, Arlington, Grand Prairie, North Richland Hills and Saginaw, Texas.

600 W 6th St Ste 481, Fort Worth, TX 76102, USA

Contact Now

Office Info

(817) 634-0007

Hours

Monday to Friday 7am to 7pm

Electrical Signage Notice

Electrical Signage Notice: Elevated Exposure Signs and Graphics provides design, fabrication coordination, and project management services for illuminated signage. All electrical installation work is performed by properly licensed Texas electrical sign contractors in accordance with state and local regulations.

Copyright @2026 | Privacy Policy | Terms and Conditions | SiteMap